Fridge troubleshooter

  1. The problem: It's not cooling, or not cold enough Change
  2. Yellow residue or ammonia smell: No Change
  3. Electric vs. propane: Both work, but it doesn't get cold enough Change
  4. Worst: All the time Change
  5. Fans: No fans, or not sure Change
  6. Parked level: Yes, it's level Change
  7. Door seals tight: Yes, they're tight Change
  8. Cooling unit age: 5 years or more Change

Likely needs a new cooling unit

The cooling unit may be getting weak

It cools on both, the RV is level and the door seals are good, but it never gets cold enough, and the unit has some years on it. That usually means it's wearing out.

What to try

  1. Check the thermistor (the temperature sensor clipped to the fins inside the fridge): unclip it and let the fridge run 12 hours. If it gets colder, the thermistor is the problem.
  2. Make sure air can flow through the back: nothing blocking the outside access door or the roof vent.
  3. If it's still not cold, call us with your model number.

Find your cooling unit by model numberFrost Guard fans

David Force Emailing or calling us? Tell us:

  • Your fridge's model number (on the sticker inside the fridge)
  • The problem: It's not cooling, or not cold enough
  • Yellow residue or ammonia smell: No
  • Electric vs. propane: Both work, but it doesn't get cold enough
  • Worst: All the time
  • Fans: No fans, or not sure
  • Parked level: Yes, it's level
  • Door seals tight: Yes, they're tight
  • Cooling unit age: 5 years or more
  • Norcold: whether your heating element has a 45° or a 90° bend

Email is best: the button below writes these answers into the email for you, and David will reply with answers to your questions.